Tolfenpyrad Rapid Test Kit
Tolfenpyrad Rapid Test Kit
Tolfenpyrad Rapid Test Kit
Tolfenpyrad Rapid Test Kit
Tolfenpyrad Rapid Test Kit
Tolfenpyrad Rapid Test Kit
FOB
Brand::
FSTest
Shelf life::
12 months
Application::
Engineered for the qualitative detection of tolfenpyrad residues in fresh fruits and vegetables.
образец:Платная поддержкаПолучить образцы
Детали продукта
Необходимые детали
Артикул продукта:23121(PR32.4584.5)
Введение в продукт

FSTest Tolfenpyrad Rapid Test Kit (10 Tests)

Product Overview

The FSTest Tolfenpyrad Rapid Test Kit (Colloidal Gold) is a professional-grade, rapid screening tool engineered for the qualitative detection of tolfenpyrad residues in fresh fruits and vegetables. Tolfenpyrad is a widely applied pyrazole insecticide and acaricide critical to global agricultural pest management and modern crop protection. Ensuring strict residue tracking is vital for agricultural growers, fresh food supply chain operators, and export compliance auditors striving to conform with international food safety standards and Maximum Residue Limits (MRLs).

By eliminating the immediate necessity for complex and costly laboratory infrastructure (such as HPLC or GC-MS), this field-ready assay compresses agricultural chemical extraction into a simplified, room-temperature workflow. It serves as an indispensable first-line defense in fresh produce logistics, crop harvesting hubs, and corporate quality compliance screening programs.

Product Highlights & Key Benefits

· High-Speed Field Turnaround: Complete the entire screening assay workflow and achieve highly reliable visual result readouts within just 5 to 8 minutes post-sample-preparation.

· Highly Sensitive Screening: Calibrated to yield dependable qualitative screening at a strict Limit of Detection (LOD) of 0.5 mg/kg (ppm) across various fruit and vegetable matrices.

· Fully Self-Contained Kit Architecture: Arrives fully packed with all necessary consumables—including 10 test cassettes, 10 microwells, 1 bottle of dedicated extracting solution (45 mL), 2 sampling bottles (30 mL), and a comprehensive user manual.

· Definite Visual Interpretation: Utilizes a competitive sandwich lateral flow immunochromatographic assay format where the color intensity of the Test (T) line shares an opposite correspondence with the tolfenpyrad concentration, eliminating analytical ambiguity.

· High Specificity & Zero Cross-Reactivity: Proven to stay entirely unaffected by non-target agrochemicals. Samples containing 1 mg/L of common alternative treatments—including Chlorpyrifos, Triazophos, Acetamiprid, and Chlorothalonil—consistently return clear negative results.

· Reliable Shelf-Life & Logistics: Unopened test kits can be safely kept tightly sealed in a cool, dry location between 4–30°C for a full guaranteed shelf-life of up to 12 months. Do not freeze.

Technical Principle: Lateral Flow Immunochromatography

The test strip is based on a sandwich lateral flow immunochromatography mechanism. The test cassette houses an integrated testing window containing an invisible Test (T) zone and a Control (C) zone before fluidics activation.

Extracted Insecticide Residues + Antibody-Conjugates -> Lateral Flow -> Reaction with Pre-coated Recombinant Antigens -> Faded or Absent T-Line (Inhibitory Response)

When a treated sample solution is dispensed into the sample well of the device, the liquid migrates laterally across the surface of the test strip via capillary action and reacts with pre-coated recombinant antigens. The intensity of color on the T test line has an opposite correspondence with the tolfenpyrad concentration in the sample. If the pesticide residue meets or exceeds the targeted detection threshold, it alters the binding kinetics, causing the T line to fade visibly or disappear entirely. For a clean, negative sample, a strong, distinct red band forms at the T zone. The Control (C) line must always develop after a sample is applied to confirm the test fluidics are functional and valid.

Specifications & General Parameters

Parameter

Product Specification

Target Analyte

Tolfenpyrad (Insecticide/Acaricide Residue) (CAS: 129558-76-5)

Molecular Formula & Weight

C21H22ClN3O2 | 383.9 g/mol

Applicable Matrix

Comprehensive range of fresh fruits and vegetables

Limit of Detection (LOD)

0.5 mg/kg (ppm)

Assay Run Time

5–8 minutes (Strictly invalid after 8 minutes)

Step-by-Step Procedure

1. Simple Sample Extraction & Preparation

·  Comminution: Cut the fresh fruit or vegetable sample into small pieces (approx. 0.5 cm x 0.5 cm).

·  Primary Extraction: Weigh exactly 2 g of sample pieces into a 30 mL sampling bottle and mix with 4 mL of the provided extracting solution.

·  Mixing & Settling: Vortex or shake the bottle thoroughly for 1 minute, then let it stand undisturbed for 1 minute to allow the layers to settle. (Note: If the resulting supernatant liquid layer is cloudy or not completely clear, transfer 1 mL of fluid into a centrifuge tube and centrifuge at 4000 rpm for 3 minutes to obtain clear test solution).

2. Running the Assay

· Prior to testing, ensure the test cassette has equilibrated to a proper operating temperature environment (20–40 degrees C) and place the device on a flat surface.

· Pipette exactly 100 uL of the prepared final sample solution into a reagent microwell, mix for 3 to 5 times using the pipette fluidics, and let it stand undisturbed for 3 minutes.

· Transfer all of the mixed solution from the microwell directly into the sample well on the test cassette.

· Interpret the visual results between 5 to 8 minutes. (Do not read after 8 minutes, as late chemical shifts render the test invalid).

Results Determination & Action Guide

· Negative (-): Both the Control (C) line and Test (T) line develop color normally. This confirms that tolfenpyrad insecticide residues are safely below the targeted regulatory threshold limit.

· Positive (+): The Control (C) line develops normally, but the Test (T) line is visibly lighter or fails to appear completely. This indicates that insecticide residues meet or exceed the designated cutoff limit.

· Invalid: The Control (C) line fails to show any visible color band, regardless of the appearance of the T line. This signals an operational error, an uncalibrated pipette, or a compromised strip. The sample must be re-tested using a brand new cassette.

Storage & Packing Specifications

· Kit Capacity:10 tests per box (Test cassettes x 10, Microwell x 10, Extracting solution (45 mL) x 1, 30mL sampling bottles x 2, User manual).

· Storage Environment:Store tightly sealed in a cool, dry location between 4–30 degrees C. Do not freeze.

· Shelf Life:12 months under proper sealed storage parameters.

Продукты

Решение для АТФ и гигиенической чистоты

Решение для пищевых патогенов

Решения для фруктов, овощей и продуктов

Решение для молочных продуктов и воды

Решение для микотоксинов


Oil Solution

Drug Residue Solution